How to arrange shuttering magnets along the length of the component?
Arrange them at equal intervals along the length according to the calculated quantity. For on-site construction, it is recommended to take a clear spacing of 1000mm, with the allowance at both ends evenly distributed. All shuttering magnets shall be uniformly arranged at the rigid back edge at the bottom of the formwork to prioritize the lateral pressure resistance of the lower part.
26
How to convert between rated vertical suction and effective horizontal resistance of a shuttering magnet?
The nominal value of a shuttering magnet is vertical suction force. When used to resist horizontal formwork expansion force, it shall be converted according to the 0.5 horizontal resistance reduction coefficient commonly used in the prefabrication industry. Example: For a shuttering magnet with a rated vertical suction of 24kN per unit, effective horizontal resistance = 24kN × 0.5 = 12kN per unit.
27
What is the function of the shuttering magnet cleaning machine? Can it restore magnetism?
The shuttering magnet cleaning machine can efficiently remove stubborn attachments such as concrete residues and iron filings on the suction surface, eliminate suction loss caused by gaps, help restore the effective suction of shuttering magnets that "demagnetize" due to dirty contact surfaces, and extend the service life of shuttering magnets.
28
Can the suction of a shuttering magnet be restored by overall magnetization?
No, overall magnetization is not feasible. A shuttering magnet is assembled with multiple magnets of different polarities, and cannot be magnetized as a whole in a magnetizer like a single magnet. To restore suction, you must first identify the specific cause, and restore magnetism through targeted measures such as cleaning the contact surface, repairing the assembly structure, and replacing damaged magnets.
29
Will shuttering magnets naturally demagnetize after long-term use?
Under normal working conditions, NdFeB permanent magnets themselves will not demagnetize naturally. Most suction drops on site are not caused by natural magnetic attenuation of the magnet itself, but by reduced effective suction due to external or structural factors such as foreign matters on the contact surface, structural loosening, magnet damage, and over-temperature operation.
30
What is the operating temperature range of sintered NdFeB shuttering magnets?
The maximum operating temperature of sintered NdFeB material can reach 230°C, and even the lowest-performance grade has a maximum operating temperature of 80°C. Most conventional shuttering magnets adopt N or M grades. When the curing temperature of PC components is lower than 80°C, it has no adverse effect on the magnetism. Higher-grade materials are available for high-temperature working conditions.
31
What magnetic material are shuttering magnets generally made of?
Shuttering magnets are generally made of sintered neodymium-iron-boron (NdFeB) permanent magnet material. This material is widely used in scenarios ranging from ordinary suction parts, permanent magnet motors to precision electronic devices, and grades with different performance levels can be selected according to working conditions.
We have been designing and producing shuttering magnets and magnetic assemblies for precast concrete for 18 years
Contact Us
Contact: Jennifer Ding
Tel: +86 18758323209
Email:sales3@saixinprecast.com
WhatsApp: +86 18758323209
Address: Building 28, Yinggong Intelligent Manufacturing Industrial Park, Heyi Village, Jiangshan Town, Yinzhou District, Ningbo
Copyright © 2026 Ningbo Saixin Magnetic Technology Co.,Ltd - www.shuttering-magnets.com | Sitemap privacy policy               浙ICP备17019829号-3
Contact us
whatsapp
Contact customer service
Contact us
whatsapp
cancel
Customer service